The TGA kit provides direct information on the thrombogenicity of a biomaterial (i.e. its propensity to induce blood clotting).

TGA kit (20 determinations)

Price (EU): €650 (valid from 01-01-2026)
Customers outside the European Union: please request a quotation.


Order test kit
TGA test kit
Description

Thrombin is a key enzyme of the coagulation cascade. Its measurement provides direct information on the thrombogenicity of a biomaterial (i.e. its propensity to induce blood clotting). In plasma, thrombin is incorporated into the fibrin network and rapidly inactivated by antithrombin and other protease inhibitors. Because of its short half-life, thrombin is difficult to measure accurately. HaemoScan therefore developed the Thrombin Generation Assay [1], which uses a specially prepared plasma to determine thrombin activity in an incubation medium after exposure to a biomaterial. This method is suitable for evaluating the haemocompatibility of biomaterials and medical devices according to the international standard ISO 10993-4:2017.

[1] van Oeveren W, Haan J, Lagerman P, Schoen P. Comparison of coagulation activity tests in vitro for selected biomaterials. Artif Organs. 2002;26(6):506–11.

Application

Measurement of biomaterial-induced thrombin generation. This kit is intended for laboratory research use only and is not for use in diagnostic or therapeutic procedures. The analysis should be performed by trained laboratory professionals.

Principle

The TGA gives an indication of the thrombogenicity of a biomaterial. The amount and speed of thrombin formation, when the biomaterial is incubated in modified plasma, is measured and compared to that of reference materials. The kit includes reference materials of high and low reactivity: one metal and two polymers. It is recommended to include at least two reference materials in each analysis. Reference materials can be selected to compare with the activities of the test samples.
Materials are first incubated in plasma. Addition of the TGA reagent initiates thrombin generation, which is measured at several time points. The concentration of thrombin is determined by enzymatic reaction with a thrombin-specific chromogenic substrate, yielding a yellow-coloured product in proportion to the amount of thrombin.
The thrombin concentrations of the samples can be determined from a calibration curve. A thrombin generation curve for each material is constructed by plotting the thrombin concentrations versus the time points at which the samples were taken. This curve is used to determine the speed of thrombin generation, which is expressed per cm2 of sample surface area. The results of the tested materials in relation to the reference materials may be used to evaluate the thrombogenicity.
The kit is designed to determine thrombin-generating activity of small samples of biomaterial. Larger samples can also be used as long as the ratio between TGA plasma and material size is respected.

Storage and Stability

Product is stable at -20 °C for at least six months.

Download

Manual / SDS

Publications using the TGA kit:
  1. Contreras-Almengor O, Ordoño J, Li M, Matykina E, Avella M, Echeverry-Rendón M, Diaz-Lantada A, Molina-Aldareguia JM. Effect of surface modification methods on 3D-printed NiTi alloys for cardiovascular applications. Biomater Adv. 2025 Aug;173:214281.

  2. Chen MJ, Pappas GA, Massella D, Schlothauer A, Motta SE, Falk V, Cesarovic N, Ermanni P. Tailoring crystallinity for hemocompatible and durable PEEK cardiovascular implants. Biomater Adv. 2023 Mar;146:213288.

  3. Iancu IM, Schröder V, Apetroaei M-R, Crețu RM, Mireșan H, Honcea A, Iancu V, Bucur LA, Mitea G, Atodiresei-Pavalache G. Biocompatibility of Membranes Based on a Mixture of Chitosan and Lythri herba Aqueous Extract. Applied Sciences. 2023; 13(14):8023.

  4. Zaytseva P, Visser VL, Ehterami A, Hoerstrup SP, Motta SE, Emmert MY. Xenogeneic Serum-Free Human Cell-Derived Tissue Engineered Matrices for the Development of Clinical-Grade Biomimetic Cardiovascular Devices. Adv Ther (Weinh). 2023;6:2300041.

  5. Manivasagam VK, Popat KC. Improved hemocompatibility on Superhemophobic Micro-Nano-Structured Titanium Surfaces. Bioengineering. 2022 Dec 29;10(1):43.

  6. Virk HS, Popat KC. Erythrocyte interaction with titanium nanostructured surfaces. In Vitro Model. 2022 Aug 31;1(4-5):347-63.

  7. Echeverry-Rendon M, Duque V, Quintero D, Robledo SM, Harmsen MC, Echeverria F. Improved corrosion resistance of commercially pure magnesium after its modification by plasma electrolytic oxidation with organic additives. J Biomater Appl. 2018 Nov;33(5):725-740.

  8. Naso F, Stefanelli U, Buratto E, Lazzari G, Perota A, Galli C, Gandaglia A. Alpha-Gal Inactivated Heart Valve Bioprostheses Exhibit an Anti-Calcification Propensity Similar to Knockout Tissues. Tissue Eng Part A. 2017 Oct;23(19-20):1181-1195.

  9. Leszczak V, Popat KC. Improved in vitro blood compatibility of polycaprolactone nanowire surfaces. ACS Appl Mater Interfaces. 2014 Sep 24;6(18):15913-24.

  10. Jovanovic D, et al. Polyacylurethanes as novel degradable cell carrier materials for tissue engineering. Materials, 2011, 4.10: 1705-1727.

  11. Jovanovic D, Engels GE, Plantinga JA, Bruinsma M, van Oeveren W, Schouten AJ, van Luyn MJ, Harmsen MC. Novel polyurethanes with interconnected porous structure induce in vivo tissue remodeling and accompanied vascularization. J Biomed Mater Res A. 2010 Oct;95(1):198-208.

  12. Krenning G, van der Strate BW, Schipper M, van Seijen XJ, Fernandes BC, van Luyn MJ, Harmsen MC. CD34+ cells augment endothelial cell differentiation of CD14+ endothelial progenitor cells in vitro. J Cell Mol Med. 2009 Aug;13(8B):2521-33.

  13. Krenning G, Dankers PY, Drouven JW, Waanders F, Franssen CF, van Luyn MJ, Harmsen MC, Popa ER. Endothelial progenitor cell dysfunction in patients with progressive chronic kidney disease. Am J Physiol Renal Physiol. 2009 Jun;296(6):F1314-22.

  14. Yoshizaki T, Tabuchi N, van Oeveren W, Shibamiya A, Koyama T, Sunamori M. PMEA polymer-coated PVC tubing maintains anti-thrombogenic properties during in vitro whole blood circulation. Int J Artif Organs. 2005 Aug;28(8):834-40.